Multi-sensor alarm
The Technical Handbook – Domestic, published by Scottish Ministers to provide guidance on the Scottish building standards suggests there are 4 main types of fire detector used in dwellings:
- Optical smoke alarms.
- Ionisation smoke alarms.
- Multi-sensor alarms.
- Heat alarms.
Alarms may be hard wired or battery operated, and may be interconnected so that if one detector is triggered, all interconnected alarms sound.
It is important that the right type of fire detector is used for different situations, as false alarms can result in occupants ignoring or disabling fire detection and fire alarm systems.
The most common causes of false alarms are:
Multi-sensor alarms (or multi-criteria alarms) detect more than one fire phenomena, for example optical and heat detection. They may also include other detection capabilities, such as carbon monoxide detection.
A multi-sensor alarm provides early warning of fire and can significantly reduce the number of unwanted false alarms in certain circumstances.
Research by BRE, published in 2014, suggested that replacement of existing detectors in Kings College London with intelligent multi-sensor detectors could reduce false alarms by 69%, and that in the general building stock, the increased use of multi-sensor detectors may avert false alarms from common causes such as cooking fumes, steam and so on. Ref The causes of false fire alarms in buildings.
Intelligent multi-sensor alarms are independently addressed and continuously monitored to verify correct operation. They may also have adjustable sensitivity settings and drift compensation to account for environmental conditions. This can help identify when an alarm is genuine, as opposed to resulting from a maintenance issue or incorrect setting.
In dwellings, multi-sensor alarms are recommended in hallways and stairwells adjacent to bathrooms or shower rooms to reduce the number of unwanted false alarms.
For more information, see the BS 5839 series of standards for fire detection and fire alarm systems for buildings.
[edit] Related articles on Designing Buildings
- Carbon monoxide.
- Carbon monoxide detector.
- Electrotechnical industry gears up for All-IP switch.
- Fire.
- Fire detection and alarm system.
- Fire fatalities in Scotland.
- Heat alarm.
- Intruder alarm.
- Ionisation smoke alarms.
- Live investigations of false fire alarms.
- New requirements for fire detection and alarm network systems IP 12 13.
- Optical smoke alarm.
- Over £1 billion lost every year due to false alarms.
- Smoke detection in high ceiling spaces.
- Smoke detector.
- The causes of false fire alarms in buildings.
Featured articles and news
Art of Building CIOB photographic competition public vote
The last week to vote for a winner until 10 January 2025.
The future of the Grenfell Tower site
Principles, promises, recommendations and a decision expected in February 2025.
20 years of the Chartered Environmentalist
If not now, when?
Journeys in Industrious England
Thomas Baskerville’s expeditions in the 1600s.
Top 25 Building Safety Wiki articles of 2024
Take a look what most people have been reading about.
Life and death at Highgate Cemetery
Balancing burials and tourism.
The 25 most read articles on DB for 2024
Design portion to procurement route and all between.
The act of preservation may sometimes be futile.
Twas the site before Christmas...
A rhyme for the industry and a thankyou to our supporters.
Plumbing and heating systems in schools
New apprentice pay rates coming into effect in the new year
Addressing the impact of recent national minimum wage changes.
EBSSA support for the new industry competence structure
The Engineering and Building Services Skills Authority, in working group 2.
Notes from BSRIA Sustainable Futures briefing
From carbon down to the all important customer: Redefining Retrofit for Net Zero Living.
Principal Designer: A New Opportunity for Architects
ACA launches a Principal Designer Register for architects.